source:本站author:admintime:2021-09-03views:332
First of all, we need to check the equipment before we encounter problems, and find out the cause first. So what is the reason for the non-uniform spraying or uneven spraying of the plasma when the atmospheric pressure plasma is sprayed? Based on the problem of “no spray or uneven spraying of ions”, we judged that the cause of the problem may be the cause of the air pressure failure.
Based on this reason, we will continue to check in depth, is it caused by the large fluctuations of the air source pressure and the air source? In response to this situation, do we have shot countermeasures?
First of all, we have to check the air source to see if the input air source pressure meets the equipment requirements.
Secondly, adjust the air pressure knob, observe whether there is any change or no change in the display of the air pressure gauge, and check the air circuit such as the solenoid valve.
The above is the relevant content of "How to deal with the situation that atmospheric pressure plasma does not spray when spraying or uneven spraying ions when the atmospheric pressure plasma encounters" for you, I hope it will be helpful to you, if you want to know more Please pay more attention to Seismic Shares!